SPONTANEOUS START-UP OF A PUMP UNIT

Authors

  • Ermatov Qobuljon Muminovich Candidate of Technical Sciences, Senior Researcher, Andijan State Technical Institute, Andijan, Uzbekistan

Keywords:

Centrifugal pump, transient process, mathematical modeling, self-starting, hydraulic shock, energy efficiency.

Abstract

The article examines the mathematical modeling of the processes involved in the spontaneous start-up of a D630-90 centrifugal pump. A dynamic model has been developed that incorporates hydraulic, mechanical, and energy equations. It is shown that a smooth start lasting 8–10 seconds reduces pressure fluctuations by 35–40% and increases energy efficiency by 8–10%. The conditions for the occurrence of self-starting have been identified, and measures for its prevention have been proposed. To reduce pressure fluctuations during pump start-up, it is recommended to increase the start-up time to 8–10 seconds, as well as the length of pipelines, and to use frequency converters. This approach slows the rise of the hydraulic pressure head, prevents abrupt changes in flow velocity, and reduces the force of hydraulic shock.

Downloads

Published

2026-06-09

Issue

Section

Articles

How to Cite

SPONTANEOUS START-UP OF A PUMP UNIT. (2026). Web of Discoveries: Journal of Analysis and Inventions, 4(6), 163-167. https://webofjournals.com/index.php/3/article/view/6682